|
Olympus
olympus fvmpe rs Olympus Fvmpe Rs, supplied by Olympus, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/multiphoton+microscope/FVMPE-RS+Multiphoton+Laser+Scanning+Microscope/pmc13787468-178-6-6 Average 96 stars, based on 1 article reviews
olympus fvmpe rs - by Bioz Stars,
2026-11
96/100 stars
|
Buy from Supplier |
|
Olympus
two photon microscope ![]() Two Photon Microscope, supplied by Olympus, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/multiphoton+microscope/FVMPE-RS+Multiphoton+Laser+Scanning+Microscope/pmc13781089-237-23-25 Average 96 stars, based on 1 article reviews
two photon microscope - by Bioz Stars,
2026-11
96/100 stars
|
Buy from Supplier |
|
Olympus
fluoview fvmpe rs multiphoton microscope system ![]() Fluoview Fvmpe Rs Multiphoton Microscope System, supplied by Olympus, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/multiphoton+microscope/FVMPE-RS+Multiphoton+Laser+Scanning+Microscope/pmc13763986-157-7-6 Average 96 stars, based on 1 article reviews
fluoview fvmpe rs multiphoton microscope system - by Bioz Stars,
2026-11
96/100 stars
|
Buy from Supplier |
|
Danaher Inc
stellaris 8 dive system ![]() Stellaris 8 Dive System, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/multiphoton+microscope/STELLARIS+8+DIVE+Multiphoton+Microscope/pmc13743370-310-7-6 Average 96 stars, based on 1 article reviews
stellaris 8 dive system - by Bioz Stars,
2026-11
96/100 stars
|
Buy from Supplier |
|
Danaher Inc
multiphoton microscope ![]() Multiphoton Microscope, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/multiphoton+microscope/STELLARIS+8+DIVE+Multiphoton+Microscope/pm42987820-56-19-24 Average 96 stars, based on 1 article reviews
multiphoton microscope - by Bioz Stars,
2026-11
96/100 stars
|
Buy from Supplier |
|
Olympus
two photon microscopy ![]() Two Photon Microscopy, supplied by Olympus, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/multiphoton+microscope/FVMPE-RS+Multiphoton+Laser+Scanning+Microscope/pm42973003-185-0-3 Average 96 stars, based on 1 article reviews
two photon microscopy - by Bioz Stars,
2026-11
96/100 stars
|
Buy from Supplier |
|
Nikon
a1r multiphoton confocal microscope ![]() A1r Multiphoton Confocal Microscope, supplied by Nikon, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/multiphoton+microscope/SMZ800N/pm42968554-80-8-7 Average 99 stars, based on 1 article reviews
a1r multiphoton confocal microscope - by Bioz Stars,
2026-11
99/100 stars
|
Buy from Supplier |
|
Olympus
fvmpe rs confocal microscope ![]() Fvmpe Rs Confocal Microscope, supplied by Olympus, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/multiphoton+microscope/FVMPE-RS+Multiphoton+Laser+Scanning+Microscope/pm42962843-107-6-9 Average 96 stars, based on 1 article reviews
fvmpe rs confocal microscope - by Bioz Stars,
2026-11
96/100 stars
|
Buy from Supplier |
|
Olympus
gemini olympus fvmpe rs twin laser multi photon microscope ![]() Gemini Olympus Fvmpe Rs Twin Laser Multi Photon Microscope, supplied by Olympus, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/multiphoton+microscope/FVMPE-RS+Multiphoton+Laser+Scanning+Microscope/pm42956952-108-1-2 Average 96 stars, based on 1 article reviews
gemini olympus fvmpe rs twin laser multi photon microscope - by Bioz Stars,
2026-11
96/100 stars
|
Buy from Supplier |
|
Danaher Inc
leica stellaris 8 dive ![]() Leica Stellaris 8 Dive, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/multiphoton+microscope/STELLARIS+8+DIVE+Multiphoton+Microscope/bio_rxiv__64898__2026__10__26__761942-312-15-15 Average 96 stars, based on 1 article reviews
leica stellaris 8 dive - by Bioz Stars,
2026-11
96/100 stars
|
Buy from Supplier |
Journal: Science Advances
Article Title: A state-dependent neural circuit resolves approach-avoidance conflict
doi: 10.1126/sciadv.aeg1944
Figure Lengend Snippet: ( A ) Electron microscopy reconstruction showing direct synaptic connections between PV5K1 neurons (purple) and ventral fan-shaped body neurons (vFB; FB2B, orange; see table S3). The box indicates the ROI for in vivo calcium imaging. Arrows denote medial-lateral ( x ), dorsal-ventral ( y ), and anterior-posterior ( z ) axes. ( B ) Schematic illustrating the experimental strategy used to assess functional connectivity between PV5K1 neurons (R65C07-LexA) and vFB layer 2 (FB2B) neurons (R89E07-GAL4). PV5K1 neurons were optogenetically activated using LexA-driven CsChrimson while calcium responses were recorded from FB2B neurons expressing GCaMP6s. ( C ) Representative in vivo two-photon images showing FB2B neurons (left, green; R89E07 > GCaMP6s), PV5K1 neurons (middle, magenta; R65C07 > CsChrimson::tdTomato), and the merged image (right). The dashed rectangle indicates the imaging ROI and photostimulation field within PV5K1 projections at vFB layer 2 using a GEO module (see Materials and Methods). Scale bar, 100 μm. ( D to F ) Left, mean ΔF/F 0 traces from FB2B neurons (R89E07-GAL4 > GCaMP6s) during optogenetic activation of CsChrimson-expressing PV5K1 neurons (R65C07-LexA > CsChrimson). Recordings were obtained under three conditions: laser stimulation without retinal supplementation (D), retinal supplementation without laser stimulation (E), and laser stimulation following retinal supplementation (F). Red bars indicate laser stimulation. Optogenetic activation reduces FB2B calcium responses only in retinal supplemented flies. Traces show mean ± s.e.m. Right, quantification of mean ΔF/F 0 before and after stimulation. ( G ) Summary box plot comparing mean post stimulation ΔF/F 0 across the three experimental conditions shown in panels D to F ( n = 8–14 flies per condition). Box plots show the full data range (minimum to maximum), with the median indicated by the center line. Statistical significance was assessed using paired t tests (D to F) and one-way ANOVA (G). (ns, not significant, * P < 0.05, ** P < 0.01).
Article Snippet: Three to six days old males expressing the calcium indicator GCaMP8f were dissected in sugar-free HL3 solution ( ) and placed under a
Techniques: Electron Microscopy, In Vivo, Calcium Imaging, Functional Assay, Expressing, Imaging, Activation Assay
Journal: Science Advances
Article Title: A state-dependent neural circuit resolves approach-avoidance conflict
doi: 10.1126/sciadv.aeg1944
Figure Lengend Snippet: ( A ) Schematic of the in vivo two-photon imaging setup used to monitor neural responses during 75 V electric shock. ( B to D ) ΔF/F 0 traces (mean ± s.e.m.; FB2B > GCaMP7b). Responses to electric shock (ES; yellow shading) were robust in fed (B) and starved flies without food cues (C) but suppressed in starved flies with food cues (D). ( E ) Comparison of electric shock period AUCs across conditions in B to D. Box plots show the median and full range ( n = 9–10 flies per condition; one-way ANOVA with Tukey’s HSD, *** P < 0.001). ( F ) Schematic of in vivo two-photon imaging during 75 V electric shock ±577 nm CsChrimson activation. ( G to H ) FB2B ΔF/F 0 traces (mean ± s.e.m.; R89E07-GAL4 > GCaMP6s) during two 1-min, 75 V shocks (yellow shading). PV5K1 neurons (R65C07-LexA > CsChrimson) were activated during the second shock only (G, red bar; n = 7) or were not stimulated (H; n = 10). PV5K1 activation abolished the second FB2B response (G); responses remained unchanged without stimulation (H). Right, first and second shock AUCs comparison. Paired t test (G) and paired Wilcoxon signed-rank test (H) (ns, not significant; ** P < 0.01, *** P < 0.001). ( I ) Proposed model for state- and food-dependent gating of electric shock avoidance by the LK-LHON-vFB pathway. In fed flies (I), low LK signalling keeps PV5K1 (LHONs) inactive, allowing FB2B neurons in the vFB to remain active and drive electric shock avoidance. In starved flies without food cues (II), elevated LK signalling alone is insufficient to activate PV5K1, so FB2B activity and avoidance are preserved. In starved flies with food cues (III), elevated LK signalling together with food input activates PV5K1, suppressing FB2B responses to ES, promoting food approach. Grey indicates neural inhibition; green indicates neural activation.
Article Snippet: Three to six days old males expressing the calcium indicator GCaMP8f were dissected in sugar-free HL3 solution ( ) and placed under a
Techniques: In Vivo, Multiphoton Microscopy, Comparison, Activation Assay, Activity Assay, Inhibition